Table of Content

Table of Contents

1 Report Summary 2 Chassis 2.1 Chassis1 2.1.1 Summary 2.1.2 Fans 2.1.3 IO Modules 2.1.4 PSUs 2.1.5 Servers 3 Rack-Mounts 3.1 FEX 3.1.1 FEX 2 3.1.1.1 Summary 3.1.1.2 Fans 3.1.1.3 IO Modules 3.1.1.4 PSUs 3.1.2 FEX 3 3.1.2.1 Summary 3.1.2.2 Fans 3.1.2.3 IO Modules 3.1.2.4 PSUs 3.2 Server 3.2.1 Server 1 3.2.1.1 Summary 3.2.1.2 Adapters 3.2.1.3 Disks 3.2.1.4 Fans 3.2.1.5 PSUs 3.2.2 Server 2 3.2.2.1 Summary 3.2.2.2 Adapters 3.2.2.3 Disks 3.2.2.4 Fans 3.2.2.5 PSUs 4 Fabric Interconnects


1 Report Summary

Cisco Unified Computing System (UCS) and servers unify computing, networking, management, virtualization, and storage access into a single integrated architecture. This unique architecture enables end-to-end server visibility, management, and control in both bare metal and virtual environments, and facilitates the move to cloud computing and IT-as-a-Service with Fabric-Based Infrastructure.

The computing component of the UCS is available in two versions: the B-Series (a powered chassis and full and/or half slot blade servers), and the C-series for 19-inch racks (that can be used with fabric interconnects). The compute hardware managed by the UCS Manager software on the Fabric Interconnects can be B-Series (blades), C-Series (rackmount) or a combination of the two. Both form factors use standard components, including Intel processors and DIMM memory. The servers are marketed with converged network adapter and port virtualization. Cisco UCS supports several hypervisors including VMware ESX, ESXi, Microsoft Hyper-V, Citrix XenServer and others.

The smart, programmable infrastructure of Cisco UCS simplifies and speeds enterprise-class application and service deployment in bare-metal, virtualized, and cloud computing environments. With unified model-based management, configuring hundreds of servers is as fast as configuring just one server -- with lower cost of ownership and improved business continuity.

This UCS report contains configuration details and status information about its components in the following chapters:

Report Info
Report date8/07/2014 6:12:19 PM
Report generated forCustomer
DescriptionAs-Built Documentation for project
Server Info
UCS version2.2(1b)
UCS IP10.5.1.150
Report Settings
Report TypeDirect Report
Visual styleBlu Light.css
Report ContentAll objects
Template HTMLUCS_ReportTemplate.htm
Template WordBars_Phones_Green_Blue.doc
Report Tool Info
Report Tool version10.5.1 / 8 July 2014
Report Tool LicenseLicensed [Ent 467890]

2 Chassis

This chapter contains an overview of all chassis on this Cisco Unified Computing System, followed by detailed settings for each chassis. Each chassis contains fans, I/O modules, power supply units (PSUs), and Cisco UCS B-Series blade servers for each chassis in the Cisco UCS domain. This chapter contains:

Rack-Mounts > Servers
NameVendorPIDModelUser LabelOverall StatusOperabilityPower State
Chassis 1Cisco Systems IncN20-C6508Cisco UCS 5108 Accessibility ProblemOperableOk

2.1 Chassis1

This chapter contains an overview of all chassis on this Cisco Unified Computing System, followed by detailed settings for each chassis. Each chassis contains fans, I/O modules, power supply units (PSUs), and Cisco UCS B-Series blade servers for each chassis in the Cisco UCS domain. This chapter contains:

2.1.1 Summary

This chapter contains the general properties of this chassis such as product, part, connection and status details.

Chassis > Summary
Properties
ID1
Product NameCisco UCS 5108
ModelN20-C6508
VendorCisco Systems Inc
Serial1595
Part Number
Revision0
Config Stateok
License Statuslicense-ok
Part Details
NameCisco UCS 5108
DescriptionCisco Blade Server Chassis, 6U with Eight Blade Server Slots
PIDN20-C6508
SKUN20-C6508
Connection Details
Connection PathA,B
Connection StatusA,B
Managing InstanceB
Status Details
Configuration Stateok
Operabilityoperable
Powerok
Thermalunknown

2.1.2 Fans

This chapter contains details about fan modules and the fans installed in each fan module for this chassis including product, part, connection and status details.

The following fans are present:

Chassis > Fans
NameDetails
Fan Module 1
Properties
ID1
Tray1
PID
Revision0
Serial
Vendor
Status Details
OperabilityOperable
PerformanceOk
PowerOn
ThermalOk
PresenceEquipped
Fans
Fan 1
Properties
ID1
Module1
Vendor
PID
Revision0
Serial
Status Details
OperabilityOperable
PowerOn
PerformanceOk
PresenceEquipped
Fan 2
Properties
ID2
Module1
Vendor
PID
Revision0
Serial
Status Details
OperabilityOperable
PowerOn
PerformanceOk
PresenceEquipped
Fan Module 2
Properties
ID2
Tray1
PID
Revision0
Serial
Vendor
Status Details
OperabilityOperable
PerformanceOk
PowerOn
ThermalOk
PresenceEquipped
Fans
Fan 1
Properties
ID1
Module2
Vendor
PID
Revision0
Serial
Status Details
OperabilityOperable
PowerOn
PerformanceOk
PresenceEquipped
Fan 2
Properties
ID2
Module2
Vendor
PID
Revision0
Serial
Status Details
OperabilityOperable
PowerOn
PerformanceOk
PresenceEquipped
Fan Module 3
Properties
ID3
Tray1
PID
Revision0
Serial
Vendor
Status Details
OperabilityOperable
PerformanceOk
PowerOn
ThermalOk
PresenceEquipped
Fans
Fan 1
Properties
ID1
Module3
Vendor
PID
Revision0
Serial
Status Details
OperabilityOperable
PowerOn
PerformanceOk
PresenceEquipped
Fan 2
Properties
ID2
Module3
Vendor
PID
Revision0
Serial
Status Details
OperabilityOperable
PowerOn
PerformanceOk
PresenceEquipped
Fan Module 4
Properties
ID4
Tray1
PID
Revision0
Serial
Vendor
Status Details
OperabilityOperable
PerformanceOk
PowerOn
ThermalOk
PresenceEquipped
Fans
Fan 1
Properties
ID1
Module4
Vendor
PID
Revision0
Serial
Status Details
OperabilityOperable
PowerOn
PerformanceOk
PresenceEquipped
Fan 2
Properties
ID2
Module4
Vendor
PID
Revision0
Serial
Status Details
OperabilityOperable
PowerOn
PerformanceOk
PresenceEquipped
Fan Module 5
Properties
ID5
Tray1
PID
Revision0
Serial
Vendor
Status Details
OperabilityOperable
PerformanceOk
PowerOn
ThermalOk
PresenceEquipped
Fans
Fan 1
Properties
ID1
Module5
Vendor
PID
Revision0
Serial
Status Details
OperabilityOperable
PowerOn
PerformanceOk
PresenceEquipped
Fan 2
Properties
ID2
Module5
Vendor
PID
Revision0
Serial
Status Details
OperabilityOperable
PowerOn
PerformanceOk
PresenceEquipped
Fan Module 6
Properties
ID6
Tray1
PID
Revision0
Serial
Vendor
Status Details
OperabilityOperable
PerformanceOk
PowerOn
ThermalOk
PresenceEquipped
Fans
Fan 1
Properties
ID1
Module6
Vendor
PID
Revision0
Serial
Status Details
OperabilityOperable
PowerOn
PerformanceOk
PresenceEquipped
Fan 2
Properties
ID2
Module6
Vendor
PID
Revision0
Serial
Status Details
OperabilityOperable
PowerOn
PerformanceOk
PresenceEquipped
Fan Module 7
Properties
ID7
Tray1
PID
Revision0
Serial
Vendor
Status Details
OperabilityOperable
PerformanceOk
PowerOn
ThermalOk
PresenceEquipped
Fans
Fan 1
Properties
ID1
Module7
Vendor
PID
Revision0
Serial
Status Details
OperabilityOperable
PowerOn
PerformanceOk
PresenceEquipped
Fan 2
Properties
ID2
Module7
Vendor
PID
Revision0
Serial
Status Details
OperabilityOperable
PowerOn
PerformanceOk
PresenceEquipped
Fan Module 8
Properties
ID8
Tray1
PID
Revision0
Serial
Vendor
Status Details
OperabilityOperable
PerformanceOk
PowerOn
ThermalOk
PresenceEquipped
Fans
Fan 1
Properties
ID1
Module8
Vendor
PID
Revision0
Serial
Status Details
OperabilityOperable
PowerOn
PerformanceOk
PresenceEquipped
Fan 2
Properties
ID2
Module8
Vendor
PID
Revision0
Serial
Status Details
OperabilityOperable
PowerOn
PerformanceOk
PresenceEquipped

2.1.3 IO Modules

This chapter contains details about I/O modules. I/O modules connect backplane ports and fabric ports. For each port you need on a given blade server, you need to have a corresponding I/O module. I/O modules contain product, part, backplane ports and fabric ports, connection and status details.

The following I/O modules are present:

Chassis > IO Modules
NameDetails
IO Module 1
Properties
ID1
PIDUCS-IOM-2208XP
Fabric IDA
Product NameCisco UCS 2208XP
Sideleft
VendorCisco Systems Inc
Revision0
Serial1595-1
Status Details
OperabilityOperable
PowerN/A
VoltageN/A
PerformanceN/A
ThermalOk
PresenceEquipped
Part Details
NameCisco UCS 2208XP
DescriptionCisco UCS 2208XP 8 Port I/O Module
PIDUCS-IOM-2208XP
SKUUCS-IOM-2208XP
Backplane Ports
Backplane Port 1/1
NameBackplane Port 1/1
Slot ID1
Operational StateIndeterminate
Port Channel
Fabric IDA
Peersys/chassis-1/blade-1/adaptor-1/ext-eth-1
Network TypeLAN
Transport TypeDCE
Backplane Port 1/5
NameBackplane Port 1/5
Slot ID1
Operational StateIndeterminate
Port Channel
Fabric IDA
Peersys/chassis-1/blade-2/adaptor-1/ext-eth-1
Network TypeLAN
Transport TypeDCE
Backplane Port 1/9
NameBackplane Port 1/9
Slot ID1
Operational StateIndeterminate
Port Channel
Fabric IDA
Peersys/chassis-1/blade-3/adaptor-1/ext-eth-1
Network TypeLAN
Transport TypeDCE
Backplane Port 1/13
NameBackplane Port 1/13
Slot ID1
Operational StateIndeterminate
Port Channel
Fabric IDA
Peersys/chassis-1/blade-3/adaptor-2/ext-eth-1
Network TypeLAN
Transport TypeDCE
Backplane Port 1/17
NameBackplane Port 1/17
Slot ID1
Operational StateIndeterminate
Port Channelsys/chassis-1/slot-1/host/pc-1282
Fabric IDA
Peersys/chassis-1/blade-5/adaptor-1/ext-eth-1
Network TypeLAN
Transport TypeDCE
Backplane Port 1/18
NameBackplane Port 1/18
Slot ID1
Operational StateIndeterminate
Port Channelsys/chassis-1/slot-1/host/pc-1281
Fabric IDA
Peersys/chassis-1/blade-5/adaptor-2/ext-eth-1
Network TypeLAN
Transport TypeDCE
Backplane Port 1/19
NameBackplane Port 1/19
Slot ID1
Operational StateIndeterminate
Port Channelsys/chassis-1/slot-1/host/pc-1282
Fabric IDA
Peersys/chassis-1/blade-5/adaptor-1/ext-eth-3
Network TypeLAN
Transport TypeDCE
Backplane Port 1/20
NameBackplane Port 1/20
Slot ID1
Operational StateIndeterminate
Port Channelsys/chassis-1/slot-1/host/pc-1281
Fabric IDA
Peersys/chassis-1/blade-5/adaptor-2/ext-eth-3
Network TypeLAN
Transport TypeDCE
Backplane Port 1/21
NameBackplane Port 1/21
Slot ID1
Operational StateIndeterminate
Port Channelsys/chassis-1/slot-1/host/pc-1280
Fabric IDA
Peersys/chassis-1/blade-6/adaptor-1/ext-eth-1
Network TypeLAN
Transport TypeDCE
Backplane Port 1/22
NameBackplane Port 1/22
Slot ID1
Operational StateIndeterminate
Port Channelsys/chassis-1/slot-1/host/pc-1280
Fabric IDA
Peersys/chassis-1/blade-6/adaptor-1/ext-eth-2
Network TypeLAN
Transport TypeDCE
Backplane Port 1/23
NameBackplane Port 1/23
Slot ID1
Operational StateIndeterminate
Port Channelsys/chassis-1/slot-1/host/pc-1280
Fabric IDA
Peersys/chassis-1/blade-6/adaptor-1/ext-eth-3
Network TypeLAN
Transport TypeDCE
Backplane Port 1/24
NameBackplane Port 1/24
Slot ID1
Operational StateIndeterminate
Port Channelsys/chassis-1/slot-1/host/pc-1280
Fabric IDA
Peersys/chassis-1/blade-6/adaptor-1/ext-eth-4
Network TypeLAN
Transport TypeDCE
Backplane Port 1/25
NameBackplane Port 1/25
Slot ID1
Operational StateIndeterminate
Port Channel
Fabric IDA
Peersys/chassis-1/blade-7/adaptor-1/ext-eth-1
Network TypeLAN
Transport TypeDCE
Backplane Port 1/29
NameBackplane Port 1/29
Slot ID1
Operational StateIndeterminate
Port Channel
Fabric IDA
Peersys/chassis-1/blade-7/adaptor-2/ext-eth-1
Network TypeLAN
Transport TypeDCE
Fabric Ports
Fabric Port 1/1
NameFabric Port 1/1
Slot ID1
Operational StateUp
Port Channel
Peer Slot ID1
Peer Port ID1
Fabric IDA
Acknowledgedok
Peersys/switch-A/slot-1/switch-ether/port-1
Network TypeLAN
Transport TypeDCE
Fabric Port 1/2
NameFabric Port 1/2
Slot ID1
Operational StateUp
Port Channel
Peer Slot ID1
Peer Port ID2
Fabric IDA
Acknowledgedok
Peersys/switch-A/slot-1/switch-ether/port-2
Network TypeLAN
Transport TypeDCE
IO Module 2
Properties
ID2
PIDUCS-IOM-2208XP
Fabric IDB
Product NameCisco UCS 2208XP
Sideright
VendorCisco Systems Inc
Revision0
Serial1595-2
Status Details
OperabilityOperable
PowerN/A
VoltageN/A
PerformanceN/A
ThermalOk
PresenceEquipped
Part Details
NameCisco UCS 2208XP
DescriptionCisco UCS 2208XP 8 Port I/O Module
PIDUCS-IOM-2208XP
SKUUCS-IOM-2208XP
Backplane Ports
Backplane Port 2/1
NameBackplane Port 2/1
Slot ID2
Operational StateIndeterminate
Port Channel
Fabric IDB
Peersys/chassis-1/blade-1/adaptor-1/ext-eth-2
Network TypeLAN
Transport TypeDCE
Backplane Port 2/5
NameBackplane Port 2/5
Slot ID2
Operational StateIndeterminate
Port Channel
Fabric IDB
Peersys/chassis-1/blade-2/adaptor-1/ext-eth-2
Network TypeLAN
Transport TypeDCE
Backplane Port 2/9
NameBackplane Port 2/9
Slot ID2
Operational StateIndeterminate
Port Channel
Fabric IDB
Peersys/chassis-1/blade-3/adaptor-1/ext-eth-2
Network TypeLAN
Transport TypeDCE
Backplane Port 2/13
NameBackplane Port 2/13
Slot ID2
Operational StateIndeterminate
Port Channel
Fabric IDB
Peersys/chassis-1/blade-3/adaptor-2/ext-eth-2
Network TypeLAN
Transport TypeDCE
Backplane Port 2/17
NameBackplane Port 2/17
Slot ID2
Operational StateIndeterminate
Port Channelsys/chassis-1/slot-2/host/pc-1285
Fabric IDB
Peersys/chassis-1/blade-5/adaptor-1/ext-eth-5
Network TypeLAN
Transport TypeDCE
Backplane Port 2/18
NameBackplane Port 2/18
Slot ID2
Operational StateIndeterminate
Port Channelsys/chassis-1/slot-2/host/pc-1284
Fabric IDB
Peersys/chassis-1/blade-5/adaptor-2/ext-eth-5
Network TypeLAN
Transport TypeDCE
Backplane Port 2/19
NameBackplane Port 2/19
Slot ID2
Operational StateIndeterminate
Port Channelsys/chassis-1/slot-2/host/pc-1285
Fabric IDB
Peersys/chassis-1/blade-5/adaptor-1/ext-eth-7
Network TypeLAN
Transport TypeDCE
Backplane Port 2/20
NameBackplane Port 2/20
Slot ID2
Operational StateIndeterminate
Port Channelsys/chassis-1/slot-2/host/pc-1284
Fabric IDB
Peersys/chassis-1/blade-5/adaptor-2/ext-eth-7
Network TypeLAN
Transport TypeDCE
Backplane Port 2/21
NameBackplane Port 2/21
Slot ID2
Operational StateIndeterminate
Port Channelsys/chassis-1/slot-2/host/pc-1283
Fabric IDB
Peersys/chassis-1/blade-6/adaptor-1/ext-eth-5
Network TypeLAN
Transport TypeDCE
Backplane Port 2/22
NameBackplane Port 2/22
Slot ID2
Operational StateIndeterminate
Port Channelsys/chassis-1/slot-2/host/pc-1283
Fabric IDB
Peersys/chassis-1/blade-6/adaptor-1/ext-eth-6
Network TypeLAN
Transport TypeDCE
Backplane Port 2/23
NameBackplane Port 2/23
Slot ID2
Operational StateIndeterminate
Port Channelsys/chassis-1/slot-2/host/pc-1283
Fabric IDB
Peersys/chassis-1/blade-6/adaptor-1/ext-eth-7
Network TypeLAN
Transport TypeDCE
Backplane Port 2/24
NameBackplane Port 2/24
Slot ID2
Operational StateIndeterminate
Port Channelsys/chassis-1/slot-2/host/pc-1283
Fabric IDB
Peersys/chassis-1/blade-6/adaptor-1/ext-eth-8
Network TypeLAN
Transport TypeDCE
Backplane Port 2/25
NameBackplane Port 2/25
Slot ID2
Operational StateIndeterminate
Port Channel
Fabric IDB
Peersys/chassis-1/blade-7/adaptor-1/ext-eth-2
Network TypeLAN
Transport TypeDCE
Backplane Port 2/29
NameBackplane Port 2/29
Slot ID2
Operational StateIndeterminate
Port Channel
Fabric IDB
Peersys/chassis-1/blade-7/adaptor-2/ext-eth-2
Network TypeLAN
Transport TypeDCE
Fabric Ports
Fabric Port 2/1
NameFabric Port 2/1
Slot ID2
Operational StateUp
Port Channel
Peer Slot ID1
Peer Port ID1
Fabric IDB
Acknowledgedok
Peersys/switch-B/slot-1/switch-ether/port-1
Network TypeLAN
Transport TypeDCE
Fabric Port 2/2
NameFabric Port 2/2
Slot ID2
Operational StateUp
Port Channel
Peer Slot ID1
Peer Port ID2
Fabric IDB
Acknowledgedok
Peersys/switch-B/slot-1/switch-ether/port-2
Network TypeLAN
Transport TypeDCE

2.1.4 PSUs

This chapter contains details about Power Supply Units (PSU) installed in this chassis including product, part and status details.

The following PSU modules are present:

Chassis > PSUs
NameDetails
PSU 1
Properties
ID1
Vendor
PID
Revision0
Serial
Firmware VersionN/A
Status Details
OperabilityOperable
PowerOn
VoltageOk
PerformanceOk
ThermalOk
PresenceEquipped
PSU 2
Properties
ID2
Vendor
PID
Revision0
Serial
Firmware VersionN/A
Status Details
OperabilityOperable
PowerOn
VoltageOk
PerformanceOk
ThermalOk
PresenceEquipped
PSU 3
Properties
ID3
Vendor
PID
Revision0
Serial
Firmware VersionN/A
Status Details
OperabilityOperable
PowerOn
VoltageOk
PerformanceOk
ThermalOk
PresenceEquipped
PSU 4
Properties
ID4
Vendor
PID
Revision0
Serial
Firmware VersionN/A
Status Details
OperabilityOperable
PowerOn
VoltageOk
PerformanceOk
ThermalOk
PresenceEquipped

2.1.5 Servers

This chapter contains details about server modules in this chassis. A server module contains processors, associated memory and use one or multiple adapters to connect to storage and networking. The properties of server modules contain product, part, connection and status details and a list of adapters.

The following server modules are present:

Chassis > Servers
NameDetails
Server 1/1
Properties
Slot ID1
Chassis ID1
VendorCisco Systems Inc
PIDN20-B6620-1
Revision0
Serial3324
UUID1b4e28ba-2fa1-11d2-0101-b9a761bde3fb
Summary
Number of Processors1
Cores6
Cores Enabled6
Threads6
Total Memory (MB)8192
Effective Memory (MB)8192
Operating Memory SpeedNot Applicable
Operating Memory VoltageNot Applicable
Adapters1
NICs0
Original UUID1b4e28ba-2fa1-11d2-0101-b9a761bde3fb
Part Details
Connection Details
Connection PathA,B
Connection StatusA,B
Managing InstanceB
Status Details
Admin StateIn Service
Discovery StateComplete
Avail StateAvailable
Assoc StateNone
Power StateOn
Slot StatusUnassociated
Check PointDiscovered
Adaptors
N20-AC0002
Properties
ID1
Product Name
PIDN20-AC0002
VendorCisco Systems Inc
Reservation0
SerialQCI1230159511G
PCI SlotN/A
IntegratedNo
Server 1/2
Properties
Slot ID2
Chassis ID1
VendorCisco Systems Inc
PIDN20-B6620-1
Revision0
Serial3325
UUID1b4e28ba-2fa1-11d2-0102-b9a761bde3fb
Summary
Number of Processors1
Cores6
Cores Enabled6
Threads6
Total Memory (MB)8192
Effective Memory (MB)8192
Operating Memory SpeedNot Applicable
Operating Memory VoltageNot Applicable
Adapters1
NICs0
Original UUID1b4e28ba-2fa1-11d2-0102-b9a761bde3fb
Part Details
Connection Details
Connection PathA,B
Connection StatusA,B
Managing InstanceB
Status Details
Admin StateIn Service
Discovery StateComplete
Avail StateAvailable
Assoc StateNone
Power StateOn
Slot StatusUnassociated
Check PointDiscovered
Adaptors
N20-AC0002
Properties
ID1
Product Name
PIDN20-AC0002
VendorCisco Systems Inc
Reservation0
SerialQCI1230159521G
PCI SlotN/A
IntegratedNo
Server 1/3
Properties
Slot ID3
Chassis ID1
VendorCisco Systems Inc
PIDN20-B6620-2
Revision0
Serial3326
UUID1b4e28ba-2fa1-11d2-0103-b9a761bde3fb
Summary
Number of Processors1
Cores6
Cores Enabled6
Threads6
Total Memory (MB)8192
Effective Memory (MB)8192
Operating Memory SpeedNot Applicable
Operating Memory VoltageNot Applicable
Adapters2
NICs2
Original UUID1b4e28ba-2fa1-11d2-0103-b9a761bde3fb
Part Details
Connection Details
Connection PathA,B
Connection StatusA,B
Managing InstanceB
Status Details
Admin StateIn Service
Discovery StateComplete
Avail StateAvailable
Assoc StateNone
Power StateOn
Slot StatusUnassociated
Check PointDiscovered
Adaptors
N20-AI0002
Properties
ID2
Product Name
PIDN20-AI0002
VendorCisco Systems Inc
Reservation0
SerialQCI1230159532G
PCI SlotN/A
IntegratedNo
N20-AC0002
Properties
ID1
Product Name
PIDN20-AC0002
VendorCisco Systems Inc
Reservation0
SerialQCI1230159531G
PCI SlotN/A
IntegratedNo
Server 1/5
Properties
Slot ID5
Chassis ID1
VendorCisco Systems Inc
PIDUCSB-B200-M3
Revision0
Serial3327
UUID1b4e28ba-2fa1-11d2-0105-b9a761bde3fb
Summary
Number of Processors1
Cores6
Cores Enabled6
Threads6
Total Memory (MB)8192
Effective Memory (MB)8192
Operating Memory SpeedNot Applicable
Operating Memory VoltageNot Applicable
Adapters2
NICs0
Original UUID1b4e28ba-2fa1-11d2-0105-b9a761bde3fb
Part Details
Connection Details
Connection PathA,B
Connection StatusA,B
Managing InstanceB
Status Details
Admin StateIn Service
Discovery StateComplete
Avail StateAvailable
Assoc StateNone
Power StateOn
Slot StatusUnassociated
Check PointDiscovered
Adaptors
UCS-VIC-M82-8P
Properties
ID2
Product Name
PIDUCS-VIC-M82-8P
VendorCisco Systems Inc
Reservation0
SerialQCI1230159552G
PCI SlotN/A
IntegratedNo
UCSB-MLOM-40G-01
Properties
ID1
Product Name
PIDUCSB-MLOM-40G-01
VendorCisco Systems Inc
Reservation0
SerialQCI1230159551G
PCI SlotN/A
IntegratedNo
Server 1/6
Properties
Slot ID6
Chassis ID1
VendorCisco Systems Inc
PIDN20-B6625-1
Revision0
Serial3328
UUID1b4e28ba-2fa1-11d2-0106-b9a761bde3fb
Summary
Number of Processors1
Cores4
Cores Enabled4
Threads8
Total Memory (MB)8192
Effective Memory (MB)8192
Operating Memory SpeedNot Applicable
Operating Memory VoltageNot Applicable
Adapters1
NICs0
Original UUID1b4e28ba-2fa1-11d2-0106-b9a761bde3fb
Part Details
Connection Details
Connection PathA,B
Connection StatusA,B
Managing InstanceB
Status Details
Admin StateIn Service
Discovery StateComplete
Avail StateAvailable
Assoc StateNone
Power StateOn
Slot StatusUnassociated
Check PointDiscovered
Adaptors
UCS-VIC-M82-8P
Properties
ID1
Product Name
PIDUCS-VIC-M82-8P
VendorCisco Systems Inc
Reservation0
SerialQCI1230159561G
PCI SlotN/A
IntegratedNo
Server 1/7
Properties
Slot ID7
Chassis ID1
VendorCisco Systems Inc
PIDN20-B6740-2
Revision0
Serial3329
UUID1b4e28ba-2fa1-11d2-0107-b9a761bde3fb
Summary
Number of Processors1
Cores4
Cores Enabled4
Threads8
Total Memory (MB)8192
Effective Memory (MB)8192
Operating Memory SpeedNot Applicable
Operating Memory VoltageNot Applicable
Adapters2
NICs2
Original UUID1b4e28ba-2fa1-11d2-0107-b9a761bde3fb
Part Details
Connection Details
Connection PathA,B
Connection StatusA,B
Managing InstanceB
Status Details
Admin StateIn Service
Discovery StateComplete
Avail StateAvailable
Assoc StateNone
Power StateOn
Slot StatusUnassociated
Check PointDiscovered
Adaptors
N20-AE0002
Properties
ID2
Product Name
PIDN20-AE0002
VendorCisco Systems Inc
Reservation0
SerialQCI1230159572G
PCI SlotN/A
IntegratedNo
N20-AC0002
Properties
ID1
Product Name
PIDN20-AC0002
VendorCisco Systems Inc
Reservation0
SerialQCI1230159571G
PCI SlotN/A
IntegratedNo

3 Rack-Mounts

This chapter contains an overview of all rack-mounts on this Cisco Unified Computing System, followed by detailed settings for each rack-mount. Rack-mounts contain FEXes and Cisco UCS C-Series rack servers integrated with the Cisco UCS domain. This chapter contains:

3.1 FEX

This chapter contains an overview of all Fabric Extenders (FEX) on this Cisco Unified Computing System, followed by detailed settings for each FEX. Each FEX contains fans, I/O modules, power supply units (PSUs).

This chapter contains:

Rack-Mounts > FEX
NameVendorPIDModelOverall Status
FEX 2Cisco SystemsN2K-C2232PP-10GECisco Nexus 2232PPAccessibility Problem
FEX 3Cisco SystemsN2K-C2232PP-10GECisco Nexus 2232PPOperable

3.1.1 FEX 2

This chapter contains an overview of all Fabric Extenders (FEX) on this Cisco Unified Computing System, followed by detailed settings for each FEX. Each FEX contains fans, I/O modules, power supply units (PSUs).

This chapter contains:

3.1.1.1 Summary

This chapter contains the general properties of this Fabric Extender (FEX) such as product, part, connection and status details.

Rack-Mounts > FEX > Summary
Properties
ID2
Product NameCisco Nexus 2232PP
VendorCisco Systems
ModelN2K-C2232PP-10GE
Revision0
Serial984
Part Details
NameCisco Nexus 2232PP
DescriptionCisco Nexus 2000 Series 32-port 10GE and 8-port 10GE SFP+ Fabric Extender
PIDN2K-C2232PP-10GE
VIDV01
Part Number800-34211-01
SKUN2K-C2232PP-10GE
Status Details
PowerN/A
VoltageN/A
ThermalN/A

3.1.1.2 Fans

This chapter contains details about fan modules and the fans installed in each fan module for this FEX including product, part, connection and status details.

The following fans are present:

Rack-Mounts > FEX > Fans
NameDetails
Fan 1
Properties
ID1
Module1
VendorCisco Systems, Inc.
PIDN2K-C2232-FAN
Revision0
SerialSAD1214958
Status Details
OperabilityOperable
PowerOn
PerformanceNot-Supported
PresenceEquipped

3.1.1.3 IO Modules

This chapter contains details about I/O modules for this FEX. I/O modules connect backplane ports and fabric ports. For each port you need on a given server, you need to have a corresponding I/O module. I/O modules contain product, part, backplane ports and fabric ports, connection and status details.

The following I/O modules are present:

Rack-Mounts > FEX > IO Modules
NameDetails
IO Module 1
Properties
ID1
PIDN2K-C2232PP-10GE
Fabric IDA
Sideleft
VendorCisco Systems
Revision0
Serial984-1
Status Details
OperabilityUnknown
PowerN/A
VoltageN/A
PerformanceN/A
ThermalUnknown
PresenceEquipped
Backplane Ports
Backplane Port 1/1
NameBackplane Port 1/1
Slot ID1
Operational StateIndeterminate
Port Channel
Fabric IDA
Peersys/rack-unit-1/mgmt/if-1
Network TypeLAN
Transport TypeDCE
Backplane Port 1/2
NameBackplane Port 1/2
Slot ID1
Operational StateIndeterminate
Port Channel
Fabric IDA
Peersys/rack-unit-1/adaptor-1/host-eth-1
Network TypeLAN
Transport TypeDCE
Backplane Port 1/3
NameBackplane Port 1/3
Slot ID1
Operational StateIndeterminate
Port Channel
Fabric IDA
Peersys/rack-unit-2/mgmt/if-1
Network TypeLAN
Transport TypeDCE
Backplane Port 1/4
NameBackplane Port 1/4
Slot ID1
Operational StateIndeterminate
Port Channel
Fabric IDA
Peersys/rack-unit-2/adaptor-1/host-eth-1
Network TypeLAN
Transport TypeDCE
Backplane Port 1/5
NameBackplane Port 1/5
Slot ID1
Operational StateIndeterminate
Port Channel
Fabric IDA
Peer
Network TypeLAN
Transport TypeDCE
Backplane Port 1/6
NameBackplane Port 1/6
Slot ID1
Operational StateIndeterminate
Port Channel
Fabric IDA
Peer
Network TypeLAN
Transport TypeDCE
Backplane Port 1/7
NameBackplane Port 1/7
Slot ID1
Operational StateIndeterminate
Port Channel
Fabric IDA
Peer
Network TypeLAN
Transport TypeDCE
Backplane Port 1/8
NameBackplane Port 1/8
Slot ID1
Operational StateIndeterminate
Port Channel
Fabric IDA
Peer
Network TypeLAN
Transport TypeDCE
Backplane Port 1/9
NameBackplane Port 1/9
Slot ID1
Operational StateIndeterminate
Port Channel
Fabric IDA
Peer
Network TypeLAN
Transport TypeDCE
Backplane Port 1/10
NameBackplane Port 1/10
Slot ID1
Operational StateIndeterminate
Port Channel
Fabric IDA
Peer
Network TypeLAN
Transport TypeDCE
Backplane Port 1/11
NameBackplane Port 1/11
Slot ID1
Operational StateIndeterminate
Port Channel
Fabric IDA
Peer
Network TypeLAN
Transport TypeDCE
Backplane Port 1/12
NameBackplane Port 1/12
Slot ID1
Operational StateIndeterminate
Port Channel
Fabric IDA
Peer
Network TypeLAN
Transport TypeDCE
Backplane Port 1/13
NameBackplane Port 1/13
Slot ID1
Operational StateIndeterminate
Port Channel
Fabric IDA
Peer
Network TypeLAN
Transport TypeDCE
Backplane Port 1/14
NameBackplane Port 1/14
Slot ID1
Operational StateIndeterminate
Port Channel
Fabric IDA
Peer
Network TypeLAN
Transport TypeDCE
Backplane Port 1/15
NameBackplane Port 1/15
Slot ID1
Operational StateIndeterminate
Port Channel
Fabric IDA
Peer
Network TypeLAN
Transport TypeDCE
Backplane Port 1/16
NameBackplane Port 1/16
Slot ID1
Operational StateIndeterminate
Port Channel
Fabric IDA
Peer
Network TypeLAN
Transport TypeDCE
Backplane Port 1/17
NameBackplane Port 1/17
Slot ID1
Operational StateIndeterminate
Port Channel
Fabric IDA
Peer
Network TypeLAN
Transport TypeDCE
Backplane Port 1/18
NameBackplane Port 1/18
Slot ID1
Operational StateIndeterminate
Port Channel
Fabric IDA
Peer
Network TypeLAN
Transport TypeDCE
Backplane Port 1/19
NameBackplane Port 1/19
Slot ID1
Operational StateIndeterminate
Port Channel
Fabric IDA
Peer
Network TypeLAN
Transport TypeDCE
Backplane Port 1/20
NameBackplane Port 1/20
Slot ID1
Operational StateIndeterminate
Port Channel
Fabric IDA
Peer
Network TypeLAN
Transport TypeDCE
Backplane Port 1/21
NameBackplane Port 1/21
Slot ID1
Operational StateIndeterminate
Port Channel
Fabric IDA
Peer
Network TypeLAN
Transport TypeDCE
Backplane Port 1/22
NameBackplane Port 1/22
Slot ID1
Operational StateIndeterminate
Port Channel
Fabric IDA
Peer
Network TypeLAN
Transport TypeDCE
Backplane Port 1/23
NameBackplane Port 1/23
Slot ID1
Operational StateIndeterminate
Port Channel
Fabric IDA
Peer
Network TypeLAN
Transport TypeDCE
Backplane Port 1/24
NameBackplane Port 1/24
Slot ID1
Operational StateIndeterminate
Port Channel
Fabric IDA
Peer
Network TypeLAN
Transport TypeDCE
Backplane Port 1/25
NameBackplane Port 1/25
Slot ID1
Operational StateIndeterminate
Port Channel
Fabric IDA
Peer
Network TypeLAN
Transport TypeDCE
Backplane Port 1/26
NameBackplane Port 1/26
Slot ID1
Operational StateIndeterminate
Port Channel
Fabric IDA
Peer
Network TypeLAN
Transport TypeDCE
Backplane Port 1/27
NameBackplane Port 1/27
Slot ID1
Operational StateIndeterminate
Port Channel
Fabric IDA
Peer
Network TypeLAN
Transport TypeDCE
Backplane Port 1/28
NameBackplane Port 1/28
Slot ID1
Operational StateIndeterminate
Port Channel
Fabric IDA
Peer
Network TypeLAN
Transport TypeDCE
Backplane Port 1/29
NameBackplane Port 1/29
Slot ID1
Operational StateIndeterminate
Port Channel
Fabric IDA
Peer
Network TypeLAN
Transport TypeDCE
Backplane Port 1/30
NameBackplane Port 1/30
Slot ID1
Operational StateIndeterminate
Port Channel
Fabric IDA
Peer
Network TypeLAN
Transport TypeDCE
Backplane Port 1/31
NameBackplane Port 1/31
Slot ID1
Operational StateIndeterminate
Port Channel
Fabric IDA
Peer
Network TypeLAN
Transport TypeDCE
Backplane Port 1/32
NameBackplane Port 1/32
Slot ID1
Operational StateIndeterminate
Port Channel
Fabric IDA
Peer
Network TypeLAN
Transport TypeDCE
Fabric Ports
Fabric Port 1/1
NameFabric Port 1/1
Slot ID1
Operational StateUp
Port Channel
Peer Slot ID1
Peer Port ID3
Fabric IDA
Acknowledgedok
Peersys/switch-A/slot-1/switch-ether/port-3
Network TypeLAN
Transport TypeDCE
Fabric Port 1/2
NameFabric Port 1/2
Slot ID1
Operational StateUp
Port Channel
Peer Slot ID1
Peer Port ID4
Fabric IDA
Acknowledgedok
Peersys/switch-A/slot-1/switch-ether/port-4
Network TypeLAN
Transport TypeDCE

3.1.1.4 PSUs

This chapter contains details about Power Supply Units (PSU) installed in this FEX including product, part and status details.

The following PSU modules are present:

Rack-Mounts > FEX > PSUs
NameDetails
PSU 1
Properties
ID1
Product Name400W power supply unit for N2K/100-240VAC
VendorCisco Systems, Inc.
PIDN2200-PAC-400W
Revision0
SerialDTH1218892
Firmware VersionN/A
Status Details
OperabilityOperable
PowerOn
VoltageUnknown
PerformanceNot-Supported
ThermalNot-Supported
PresenceEquipped
Part Details
Name400W power supply unit for N2K/100-240VAC
Description400W power supply unit for N2K/100-240VAC
PIDN2200-PAC-400W
VIDV01
SKUN2200-PAC-400W

3.1.2 FEX 3

This chapter contains an overview of all Fabric Extenders (FEX) on this Cisco Unified Computing System, followed by detailed settings for each FEX. Each FEX contains fans, I/O modules, power supply units (PSUs).

This chapter contains:

3.1.2.1 Summary

This chapter contains the general properties of this Fabric Extender (FEX) such as product, part, connection and status details.

Rack-Mounts > FEX > Summary
Properties
ID3
Product NameCisco Nexus 2232PP
VendorCisco Systems
ModelN2K-C2232PP-10GE
Revision0
Serial985
Part Details
NameCisco Nexus 2232PP
DescriptionCisco Nexus 2000 Series 32-port 10GE and 8-port 10GE SFP+ Fabric Extender
PIDN2K-C2232PP-10GE
VIDV01
Part Number800-34211-01
SKUN2K-C2232PP-10GE
Status Details
PowerN/A
VoltageN/A
ThermalN/A

3.1.2.2 Fans

This chapter contains details about fan modules and the fans installed in each fan module for this FEX including product, part, connection and status details.

The following fans are present:

Rack-Mounts > FEX > Fans
NameDetails
Fan 1
Properties
ID1
Module1
VendorCisco Systems, Inc.
PIDN2K-C2232-FAN
Revision0
SerialSAD1214959
Status Details
OperabilityOperable
PowerOn
PerformanceNot-Supported
PresenceEquipped

3.1.2.3 IO Modules

This chapter contains details about I/O modules for this FEX. I/O modules connect backplane ports and fabric ports. For each port you need on a given server, you need to have a corresponding I/O module. I/O modules contain product, part, backplane ports and fabric ports, connection and status details.

The following I/O modules are present:

Rack-Mounts > FEX > IO Modules
NameDetails
IO Module 1
Properties
ID1
PIDN2K-C2232PP-10GE
Fabric IDB
Sideleft
VendorCisco Systems
Revision0
Serial985-1
Status Details
OperabilityUnknown
PowerN/A
VoltageN/A
PerformanceN/A
ThermalUnknown
PresenceEquipped
Backplane Ports
Backplane Port 1/1
NameBackplane Port 1/1
Slot ID1
Operational StateIndeterminate
Port Channel
Fabric IDB
Peersys/rack-unit-1/mgmt/if-2
Network TypeLAN
Transport TypeDCE
Backplane Port 1/2
NameBackplane Port 1/2
Slot ID1
Operational StateIndeterminate
Port Channel
Fabric IDB
Peersys/rack-unit-1/adaptor-1/host-eth-2
Network TypeLAN
Transport TypeDCE
Backplane Port 1/3
NameBackplane Port 1/3
Slot ID1
Operational StateIndeterminate
Port Channel
Fabric IDB
Peersys/rack-unit-2/mgmt/if-2
Network TypeLAN
Transport TypeDCE
Backplane Port 1/4
NameBackplane Port 1/4
Slot ID1
Operational StateIndeterminate
Port Channel
Fabric IDB
Peersys/rack-unit-2/adaptor-1/host-eth-2
Network TypeLAN
Transport TypeDCE
Backplane Port 1/5
NameBackplane Port 1/5
Slot ID1
Operational StateIndeterminate
Port Channel
Fabric IDB
Peer
Network TypeLAN
Transport TypeDCE
Backplane Port 1/6
NameBackplane Port 1/6
Slot ID1
Operational StateIndeterminate
Port Channel
Fabric IDB
Peer
Network TypeLAN
Transport TypeDCE
Backplane Port 1/7
NameBackplane Port 1/7
Slot ID1
Operational StateIndeterminate
Port Channel
Fabric IDB
Peer
Network TypeLAN
Transport TypeDCE
Backplane Port 1/8
NameBackplane Port 1/8
Slot ID1
Operational StateIndeterminate
Port Channel
Fabric IDB
Peer
Network TypeLAN
Transport TypeDCE
Backplane Port 1/9
NameBackplane Port 1/9
Slot ID1
Operational StateIndeterminate
Port Channel
Fabric IDB
Peer
Network TypeLAN
Transport TypeDCE
Backplane Port 1/10
NameBackplane Port 1/10
Slot ID1
Operational StateIndeterminate
Port Channel
Fabric IDB
Peer
Network TypeLAN
Transport TypeDCE
Backplane Port 1/11
NameBackplane Port 1/11
Slot ID1
Operational StateIndeterminate
Port Channel
Fabric IDB
Peer
Network TypeLAN
Transport TypeDCE
Backplane Port 1/12
NameBackplane Port 1/12
Slot ID1
Operational StateIndeterminate
Port Channel
Fabric IDB
Peer
Network TypeLAN
Transport TypeDCE
Backplane Port 1/13
NameBackplane Port 1/13
Slot ID1
Operational StateIndeterminate
Port Channel
Fabric IDB
Peer
Network TypeLAN
Transport TypeDCE
Backplane Port 1/14
NameBackplane Port 1/14
Slot ID1
Operational StateIndeterminate
Port Channel
Fabric IDB
Peer
Network TypeLAN
Transport TypeDCE
Backplane Port 1/15
NameBackplane Port 1/15
Slot ID1
Operational StateIndeterminate
Port Channel
Fabric IDB
Peer
Network TypeLAN
Transport TypeDCE
Backplane Port 1/16
NameBackplane Port 1/16
Slot ID1
Operational StateIndeterminate
Port Channel
Fabric IDB
Peer
Network TypeLAN
Transport TypeDCE
Backplane Port 1/17
NameBackplane Port 1/17
Slot ID1
Operational StateIndeterminate
Port Channel
Fabric IDB
Peer
Network TypeLAN
Transport TypeDCE
Backplane Port 1/18
NameBackplane Port 1/18
Slot ID1
Operational StateIndeterminate
Port Channel
Fabric IDB
Peer
Network TypeLAN
Transport TypeDCE
Backplane Port 1/19
NameBackplane Port 1/19
Slot ID1
Operational StateIndeterminate
Port Channel
Fabric IDB
Peer
Network TypeLAN
Transport TypeDCE
Backplane Port 1/20
NameBackplane Port 1/20
Slot ID1
Operational StateIndeterminate
Port Channel
Fabric IDB
Peer
Network TypeLAN
Transport TypeDCE
Backplane Port 1/21
NameBackplane Port 1/21
Slot ID1
Operational StateIndeterminate
Port Channel
Fabric IDB
Peer
Network TypeLAN
Transport TypeDCE
Backplane Port 1/22
NameBackplane Port 1/22
Slot ID1
Operational StateIndeterminate
Port Channel
Fabric IDB
Peer
Network TypeLAN
Transport TypeDCE
Backplane Port 1/23
NameBackplane Port 1/23
Slot ID1
Operational StateIndeterminate
Port Channel
Fabric IDB
Peer
Network TypeLAN
Transport TypeDCE
Backplane Port 1/24
NameBackplane Port 1/24
Slot ID1
Operational StateIndeterminate
Port Channel
Fabric IDB
Peer
Network TypeLAN
Transport TypeDCE
Backplane Port 1/25
NameBackplane Port 1/25
Slot ID1
Operational StateIndeterminate
Port Channel
Fabric IDB
Peer
Network TypeLAN
Transport TypeDCE
Backplane Port 1/26
NameBackplane Port 1/26
Slot ID1
Operational StateIndeterminate
Port Channel
Fabric IDB
Peer
Network TypeLAN
Transport TypeDCE
Backplane Port 1/27
NameBackplane Port 1/27
Slot ID1
Operational StateIndeterminate
Port Channel
Fabric IDB
Peer
Network TypeLAN
Transport TypeDCE
Backplane Port 1/28
NameBackplane Port 1/28
Slot ID1
Operational StateIndeterminate
Port Channel
Fabric IDB
Peer
Network TypeLAN
Transport TypeDCE
Backplane Port 1/29
NameBackplane Port 1/29
Slot ID1
Operational StateIndeterminate
Port Channel
Fabric IDB
Peer
Network TypeLAN
Transport TypeDCE
Backplane Port 1/30
NameBackplane Port 1/30
Slot ID1
Operational StateIndeterminate
Port Channel
Fabric IDB
Peer
Network TypeLAN
Transport TypeDCE
Backplane Port 1/31
NameBackplane Port 1/31
Slot ID1
Operational StateIndeterminate
Port Channel
Fabric IDB
Peer
Network TypeLAN
Transport TypeDCE
Backplane Port 1/32
NameBackplane Port 1/32
Slot ID1
Operational StateIndeterminate
Port Channel
Fabric IDB
Peer
Network TypeLAN
Transport TypeDCE
Fabric Ports
Fabric Port 1/1
NameFabric Port 1/1
Slot ID1
Operational StateUp
Port Channel
Peer Slot ID1
Peer Port ID3
Fabric IDB
Acknowledgedok
Peersys/switch-B/slot-1/switch-ether/port-3
Network TypeLAN
Transport TypeDCE
Fabric Port 1/2
NameFabric Port 1/2
Slot ID1
Operational StateUp
Port Channel
Peer Slot ID1
Peer Port ID4
Fabric IDB
Acknowledgedok
Peersys/switch-B/slot-1/switch-ether/port-4
Network TypeLAN
Transport TypeDCE

3.1.2.4 PSUs

This chapter contains details about Power Supply Units (PSU) installed in this FEX including product, part and status details.

The following PSU modules are present:

Rack-Mounts > FEX > PSUs
NameDetails
PSU 1
Properties
ID1
Product Name400W power supply unit for N2K/100-240VAC
VendorCisco Systems, Inc.
PIDN2200-PAC-400W
Revision0
SerialDTH1218893
Firmware VersionN/A
Status Details
OperabilityOperable
PowerOn
VoltageUnknown
PerformanceNot-Supported
ThermalNot-Supported
PresenceEquipped
Part Details
Name400W power supply unit for N2K/100-240VAC
Description400W power supply unit for N2K/100-240VAC
PIDN2200-PAC-400W
VIDV01
SKUN2200-PAC-400W

3.2 Server

This chapter contains details about servers installed in Cisco UCS rack-mounts. A rack-mount server contains processors, associated memory and use one or multiple adapters to connect to storage and networking. The properties of rack-mount servers contain product, part, disks, fans, PSUs, status details and a list of adapters.

This chapter contains:

Rack-Mounts > Servers
NameOverall StatusPIDModelUser LabelCoresMemoryAdaptorsNICsHBAsOperabilityPower StateAssoc State
Server 1UnassociatedR200-1120402WCisco UCS C200 M2 48192120OperableOnNone
Server 2UnassociatedR210-2121605WCisco UCS C210 M2 48192120OperableOnNone

3.2.1 Server 1

This chapter contains details about servers installed in Cisco UCS rack-mounts. A rack-mount server contains processors, associated memory and use one or multiple adapters to connect to storage and networking. The properties of rack-mount servers contain product, part, disks, fans, PSUs, status details and a list of adapters.

This chapter contains:

3.2.1.1 Summary

This chapter contains the general properties of this rack-mount server such as product, part, connection and status details.

Rack-Mounts > Server > Summary
Properties
Product NameCisco UCS C200 M2
VendorCisco Systems Inc
PIDR200-1120402W
Revision0
Serial10001
UUID1b4e28ba-2fa1-11d2-e001-b9a761bde3fb
Processors and Memory
Number of Processors1
Cores4
Cores Enabled4
Threads8
Total Memory (MB)8192
Effective Memory (MB)8192
Operating Memory SpeedNot-Applicable
Operating Memory VoltageNot-Applicable
Adapters1
NICs2
Original UUID1b4e28ba-2fa1-11d2-e001-b9a761bde3fb
Part Details
NameCisco UCS C200 M2
Description2 socket, 1RU Rack-Mount Server, 12 DIMMs, 4 LFF Disks, Intel Xeon 5500 and 5600 series, 2 PCIe slots, 2 PSUs
PIDR200-1120402W
SKUR200-1120402W
Connection Details
Connection PathA,B
Connection StatusA,B
Managing InstanceB
Status Details
Admin StateIn-Service
Discovery StateComplete
Avail StateAvailable
Assoc StateNone
Power StateOn
Slot StatusUnassociated
Check PointDiscovered

3.2.1.2 Adapters

This chapter contains details about adapters installed in this rack-mount server including product, part and installation details.

The following adapters are present:

Rack-Mounts > Server > Adapters
ModelDetails
N2XX-AIPCI01
Properties
ID1
Product Name
PIDN2XX-AIPCI01
VendorIntel Corp.
Reservation0
SerialQCI1230202111G
PCI Slot
IntegratedNo

3.2.1.3 Disks

This chapter contains details about disks installed in this rack-mount server including product, part and status details.

The following disks are present:

Rack-Mounts > Server > Disks
NameDetails
UCS-HDD500GI1F211
Disk Properties
ID1
PIDST3500514NS
VID
Product Name500GB SATA 7.2K RPM 3.5 HDD/hot plug/drive sled
VendorATA
Serial3081
Revision0
Drive StateUnknown
Power StateUnknown
Size (MB)524288000
Link SpeedUnknown
Number of blocks524288000
Block Size1024
TechnologyHDD
Part Details
Name500GB SATA 7.2K RPM 3.5 HDD/hot plug/drive sled
Description500GB SATA 7.2K RPM 3.5 HDD/hot plug/drive sled
PIDUCS-HDD500GI1F211
VIDV01
Part Number58-0147-01
SKUUCS-HDD500GI1F211
Status Details
OperabilityOperable
Oper Qualifier ReasonN/A
PresenceEquipped
Running Version12345

3.2.1.4 Fans

This chapter contains details about fan modules and the fans installed in each fan module for this server including product, part, connection and status details.

The following fans are present:

Rack-Mounts > Server > Fans
NameDetails
Fan Module 3
Properties
ID3
Tray1
PID
Revision0
SerialN/A
VendorN/A
Status Details
OperabilityOperable
PerformanceUnknown
PowerOn
ThermalNot-Supported
PresenceEquipped
Fans
Fan 1
Properties
ID1
Module3
VendorN/A
PID
Revision0
SerialN/A
Status Details
OperabilityUnknown
PowerOn
PerformanceUnknown
PresenceEquipped
Fan 2
Properties
ID2
Module3
VendorN/A
PID
Revision0
SerialN/A
Status Details
OperabilityUnknown
PowerOn
PerformanceUnknown
PresenceEquipped
Fan Module 2
Properties
ID2
Tray1
PID
Revision0
SerialN/A
VendorN/A
Status Details
OperabilityOperable
PerformanceUnknown
PowerOn
ThermalNot-Supported
PresenceEquipped
Fans
Fan 1
Properties
ID1
Module2
VendorN/A
PID
Revision0
SerialN/A
Status Details
OperabilityUnknown
PowerOn
PerformanceUnknown
PresenceEquipped
Fan 2
Properties
ID2
Module2
VendorN/A
PID
Revision0
SerialN/A
Status Details
OperabilityUnknown
PowerOn
PerformanceUnknown
PresenceEquipped
Fan Module 1
Properties
ID1
Tray1
PID
Revision0
SerialN/A
VendorN/A
Status Details
OperabilityOperable
PerformanceUnknown
PowerOn
ThermalNot-Supported
PresenceEquipped
Fans
Fan 1
Properties
ID1
Module1
VendorN/A
PID
Revision0
SerialN/A
Status Details
OperabilityUnknown
PowerOn
PerformanceUnknown
PresenceEquipped
Fan 2
Properties
ID2
Module1
VendorN/A
PID
Revision0
SerialN/A
Status Details
OperabilityUnknown
PowerOn
PerformanceUnknown
PresenceEquipped

3.2.1.5 PSUs

This chapter contains details about Power Supply Units (PSU) installed in this server including product, part and status details.

The following PSU modules are present:

Rack-Mounts > Server > PSUs
NameDetails
PSU 2
Properties
ID2
Product Name650W power supply unit for UCS C200 or C210 Server
Vendor3Y PY PO
PIDSUNNY651AM
Revision0
SerialDTH12181795
Firmware VersionN/A
Status Details
OperabilityOperable
PowerOn
VoltageUnknown
PerformanceUnknown
ThermalUnknown
PresenceEquipped
Part Details
Name650W power supply unit for UCS C200 or C210 Server
Description650W power supply unit for UCS C200 or C210 Server
PIDR2X0-PSU2-650W
VIDV00
SKUR2X0-PSU2-650W
PSU 1
Properties
ID1
Product Name650W power supply unit for UCS C200 or C210 Server
Vendor3Y PY PO
PIDSUNNY651AM
Revision0
SerialDTH12181794
Firmware VersionN/A
Status Details
OperabilityOperable
PowerOn
VoltageUnknown
PerformanceUnknown
ThermalUnknown
PresenceEquipped
Part Details
Name650W power supply unit for UCS C200 or C210 Server
Description650W power supply unit for UCS C200 or C210 Server
PIDR2X0-PSU2-650W
VIDV00
SKUR2X0-PSU2-650W

3.2.2 Server 2

This chapter contains details about servers installed in Cisco UCS rack-mounts. A rack-mount server contains processors, associated memory and use one or multiple adapters to connect to storage and networking. The properties of rack-mount servers contain product, part, disks, fans, PSUs, status details and a list of adapters.

This chapter contains:

3.2.2.1 Summary

This chapter contains the general properties of this rack-mount server such as product, part, connection and status details.

Rack-Mounts > Server > Summary
Properties
Product NameCisco UCS C210 M2
VendorCisco Systems Inc
PIDR210-2121605W
Revision0
Serial10884
UUID1b4e28ba-2fa1-11d2-e002-b9a761bde3fb
Processors and Memory
Number of Processors1
Cores4
Cores Enabled4
Threads8
Total Memory (MB)8192
Effective Memory (MB)8192
Operating Memory SpeedNot-Applicable
Operating Memory VoltageNot-Applicable
Adapters1
NICs2
Original UUID1b4e28ba-2fa1-11d2-e002-b9a761bde3fb
Part Details
NameCisco UCS C210 M2
Description2 socket, 2RU Rack-Mount Server, 12 DIMMs, 16 SFF Disks, Intel Xeon 5500 and 5600 series, 5 PCIe slots, 2 PSUs
PIDR210-2121605W
SKUR210-2121605W
Connection Details
Connection PathA,B
Connection StatusA,B
Managing InstanceB
Status Details
Admin StateIn-Service
Discovery StateComplete
Avail StateAvailable
Assoc StateNone
Power StateOn
Slot StatusUnassociated
Check PointDiscovered

3.2.2.2 Adapters

This chapter contains details about adapters installed in this rack-mount server including product, part and installation details.

The following adapters are present:

Rack-Mounts > Server > Adapters
ModelDetails
N2XX-AIPCI01
Properties
ID1
Product Name
PIDN2XX-AIPCI01
VendorIntel Corp.
Reservation0
SerialQCI1230202221G
PCI Slot
IntegratedNo

3.2.2.3 Disks

This chapter contains details about disks installed in this rack-mount server including product, part and status details.

The following disks are present:

Rack-Mounts > Server > Disks
NameDetails
UCS-HDD500GI1F211
Disk Properties
ID1
PIDST3500514NS
VID
Product Name500GB SATA 7.2K RPM 3.5 HDD/hot plug/drive sled
VendorATA
Serial3082
Revision0
Drive StateUnknown
Power StateUnknown
Size (MB)524288000
Link SpeedUnknown
Number of blocks524288000
Block Size1024
TechnologyHDD
Part Details
Name500GB SATA 7.2K RPM 3.5 HDD/hot plug/drive sled
Description500GB SATA 7.2K RPM 3.5 HDD/hot plug/drive sled
PIDUCS-HDD500GI1F211
VIDV01
Part Number58-0147-01
SKUUCS-HDD500GI1F211
Status Details
OperabilityOperable
Oper Qualifier ReasonN/A
PresenceEquipped
Running Version12345

3.2.2.4 Fans

This chapter contains details about fan modules and the fans installed in each fan module for this server including product, part, connection and status details.

The following fans are present:

Rack-Mounts > Server > Fans
NameDetails
Fan Module 5
Properties
ID5
Tray1
PID
Revision0
SerialN/A
VendorN/A
Status Details
OperabilityOperable
PerformanceUnknown
PowerOn
ThermalNot-Supported
PresenceEquipped
Fans
Fan 1
Properties
ID1
Module5
VendorN/A
PID
Revision0
SerialN/A
Status Details
OperabilityUnknown
PowerOn
PerformanceUnknown
PresenceEquipped
Fan 2
Properties
ID2
Module5
VendorN/A
PID
Revision0
SerialN/A
Status Details
OperabilityUnknown
PowerOn
PerformanceUnknown
PresenceEquipped
Fan Module 4
Properties
ID4
Tray1
PID
Revision0
SerialN/A
VendorN/A
Status Details
OperabilityOperable
PerformanceUnknown
PowerOn
ThermalNot-Supported
PresenceEquipped
Fans
Fan 1
Properties
ID1
Module4
VendorN/A
PID
Revision0
SerialN/A
Status Details
OperabilityUnknown
PowerOn
PerformanceUnknown
PresenceEquipped
Fan 2
Properties
ID2
Module4
VendorN/A
PID
Revision0
SerialN/A
Status Details
OperabilityUnknown
PowerOn
PerformanceUnknown
PresenceEquipped
Fan Module 3
Properties
ID3
Tray1
PID
Revision0
SerialN/A
VendorN/A
Status Details
OperabilityOperable
PerformanceUnknown
PowerOn
ThermalNot-Supported
PresenceEquipped
Fans
Fan 1
Properties
ID1
Module3
VendorN/A
PID
Revision0
SerialN/A
Status Details
OperabilityUnknown
PowerOn
PerformanceUnknown
PresenceEquipped
Fan 2
Properties
ID2
Module3
VendorN/A
PID
Revision0
SerialN/A
Status Details
OperabilityUnknown
PowerOn
PerformanceUnknown
PresenceEquipped
Fan Module 2
Properties
ID2
Tray1
PID
Revision0
SerialN/A
VendorN/A
Status Details
OperabilityOperable
PerformanceUnknown
PowerOn
ThermalNot-Supported
PresenceEquipped
Fans
Fan 1
Properties
ID1
Module2
VendorN/A
PID
Revision0
SerialN/A
Status Details
OperabilityUnknown
PowerOn
PerformanceUnknown
PresenceEquipped
Fan 2
Properties
ID2
Module2
VendorN/A
PID
Revision0
SerialN/A
Status Details
OperabilityUnknown
PowerOn
PerformanceUnknown
PresenceEquipped
Fan Module 1
Properties
ID1
Tray1
PID
Revision0
SerialN/A
VendorN/A
Status Details
OperabilityOperable
PerformanceUnknown
PowerOn
ThermalNot-Supported
PresenceEquipped
Fans
Fan 1
Properties
ID1
Module1
VendorN/A
PID
Revision0
SerialN/A
Status Details
OperabilityUnknown
PowerOn
PerformanceUnknown
PresenceEquipped
Fan 2
Properties
ID2
Module1
VendorN/A
PID
Revision0
SerialN/A
Status Details
OperabilityUnknown
PowerOn
PerformanceUnknown
PresenceEquipped

3.2.2.5 PSUs

This chapter contains details about Power Supply Units (PSU) installed in this server including product, part and status details.

The following PSU modules are present:

Rack-Mounts > Server > PSUs
NameDetails
PSU 2
Properties
ID2
Product Name650W power supply unit for UCS C200 or C210 Server
Vendor3Y PY PO
PIDSUNNY651AM
Revision0
SerialDTH12181797
Firmware VersionN/A
Status Details
OperabilityOperable
PowerOn
VoltageUnknown
PerformanceUnknown
ThermalUnknown
PresenceEquipped
Part Details
Name650W power supply unit for UCS C200 or C210 Server
Description650W power supply unit for UCS C200 or C210 Server
PIDR2X0-PSU2-650W
VIDV00
SKUR2X0-PSU2-650W
PSU 1
Properties
ID1
Product Name650W power supply unit for UCS C200 or C210 Server
Vendor3Y PY PO
PIDSUNNY651AM
Revision0
SerialDTH12181796
Firmware VersionN/A
Status Details
OperabilityOperable
PowerOn
VoltageUnknown
PerformanceUnknown
ThermalUnknown
PresenceEquipped
Part Details
Name650W power supply unit for UCS C200 or C210 Server
Description650W power supply unit for UCS C200 or C210 Server
PIDR2X0-PSU2-650W
VIDV00
SKUR2X0-PSU2-650W

4 Fabric Interconnects

This chapter contains details about each Fabric Interconnect module. Fabric Interconnects provide uniform access to both networks and storage. The Cisco Fabric Interconnects are a core part of the Cisco Unified Computing System and provide both network connectivity and management capabilities to all attached Cisco UCS Blade Servers.

The Cisco 6100 or 6200 Series switch (called a 'Fabric Interconnect') provides network connectivity for the chassis, blade servers and rack servers connected to it through 10 Gigabit and Fiber Channel over Ethernet (FCoE). The Fabric Interconnects are derived from the Nexus 5000 and run NX-OS as well as the UCS Manager software. The FCoE component is necessary for connection to SAN storage, since the UCS system blade servers have very little local storage capacity.

The Fabric Interconnect can further connect to multiple Fabric Extenders, Port Extenders using VNTag to the Fabric Interconnects, allowing up to 160 servers to be managed by one Fabric Interconnect (or two in Active-Active failover).

The following Fabric Interconnects are present:

Fabric Interconnects
NameDetails
A
Properties
NameA
Product NameCisco UCS 6296UP
VendorCisco Systems, Inc.
PIDUCS-FI-6296UP
Revision0
SerialJAB121800UL
Total Memory1.445GB
Part Details
NameCisco UCS 6296UP
DescriptionCisco UCS 6296UP 2RU Fabric Int/2 PSU/4 Fans/48 Fixed UP
PIDUCS-FI-6296UP
VIDV01
Part NumberUCS-FI-6296UP
SKUUCS-FI-6296UP
Status Details
Overall StatusOperable
ThermalN/A
Local Storage Information
Local Storage Information
PartitionSize (MB)Used
Bootflash00%
Workspace00%
Spare00%
Opt00%
IPv4
IP Address10.5.1.150
Subnet Mask255.255.255.0
Default Gateway10.5.1.1
IPv6
IP Address::
Prefix64
Default Gateway::
In-Band Access
Admin StateDisable
VLAN Port Count
VLAN Port Limit6001
Access VLAN Port Count0
Border VLAN Port Count0
Allocation StatusAvailable
FC Zone Count
FC Zone Limit8000
FC Zone Count0
Allocation StatusAvailable
B
Properties
NameB
Product NameCisco UCS 6296UP
VendorCisco Systems, Inc.
PIDUCS-FI-6296UP
Revision0
SerialJAB221800UL
Total Memory1.043GB
Part Details
NameCisco UCS 6296UP
DescriptionCisco UCS 6296UP 2RU Fabric Int/2 PSU/4 Fans/48 Fixed UP
PIDUCS-FI-6296UP
VIDV01
Part NumberUCS-FI-6296UP
SKUUCS-FI-6296UP
Status Details
Overall StatusOperable
ThermalN/A
Local Storage Information
Local Storage Information
PartitionSize (MB)Used
Bootflash00%
Workspace00%
Spare00%
Opt00%
IPv4
IP Address10.5.1.151
Subnet Mask255.255.255.0
Default Gateway10.5.1.1
IPv6
IP Address::
Prefix64
Default Gateway::
In-Band Access
Admin StateDisable
VLAN Port Count
VLAN Port Limit6001
Access VLAN Port Count0
Border VLAN Port Count0
Allocation StatusAvailable
FC Zone Count
FC Zone Limit8000
FC Zone Count0
Allocation StatusAvailable
Table of Contents [Hide TOC]